Containment booths provide operator, process and / or product protection by utilizing HEPA filtered unidirectional laminar downflow to maintain an ISO 5 environment at rest within the work zone and capture particulates during open handling processes.
The standard Esco DFBG2 has over 420 possible dimensional models and approximately 3.5 million possible system configurations ensuring that Esco can provide a standard solution to fit your specific process and facility requirements. Should a standard option not fit your requirements Esco can offer a customized solution.
The DFBG2 is designed such that through the different configurations it can be applied; but not limited to, the following markets:
- Pharmaceutical - Biological - Cosmetic - Animal - Nutraceutical - Robotic - Food - Electronic
Pharmacon Downflow Booth
Standard Features cGMP modular design with minimized joints and seams
6 different filter configurations available utilizing combinations of G4, F8, Carbon, H13, H14 and PLF screens
Gel Seal HEPA Filters
Integrated Filter challenge ports
Safe Change filter configurations are available for potent products, selectable to change either internally or externally to the booth
Open loop or Closed Loop fan control configurations
Recirculating or Single Pass airflow configurations allowing use for powder or solvent applications
Optional cooling coil systems to provide operator comfort
PVC strip curtains available
Energy efficient EC fan units available to minimize operating costs
Optional hazardous area configurations to meet ATEX and NEC 505 requirements.
Multiple control system options (HMI, Push Button or Sentinel Gold Microprocessor interfaces)
Modular design allows future system adjustment without full booth replacement
Basic Principles Laminar airflow velocity of 0.45m/s ± 20% (89 ft/min) measured 150mm (6") from terminal HEPA filter or diffuser face
Containment Performance Target (CPT's) ≤ 100 µg/m3 over an 8 hour Time Weighted Average (TWA) when used with proper operator techniques.
CPT's of ≤ 10 µg/m3 over an 8 hour TWA are achievable with the use of a high containment screen
ISO 5 work space environment at rest conditions
Enhanced cGMP practices
Cross contamination control through negative and positive pressure environment options
A Downflow Or Containment Booth Used In The Pharmaceutical Industry To Protect Operators From Dust
CONTAINMENT BOOTH (pdf)
DownloadThis website uses cookies. By continuing to use this site, you accept our use of cookies. Privacy Policy